dc.contributor.author | Yannas, Ioannis V. | en_US |
dc.contributor.author | Spector, Myron | en_US |
dc.coverage.temporal | Spring 2003 | en_US |
dc.date.issued | 2003-06 | |
dc.identifier | 2.782J-Spring2003 | |
dc.identifier | local: 2.782J | |
dc.identifier | local: 3.961J | |
dc.identifier | local: 20.451J | |
dc.identifier | local: HST.524J | |
dc.identifier | local: IMSCP-MD5-09bef79ba6e754d01809fa62c8c05867 | |
dc.identifier.uri | http://hdl.handle.net/1721.1/44634 | |
dc.description.abstract | Solution of clinical problems by use of implants and other medical devices. Systematic use of cell-matrix control volumes. The role of stress analysis in the design process. Anatomic fit: shape and size of implants. Selection of biomaterials. Instrumentation for surgical implantation procedures. Preclinical testing for safety and efficacy: risk/benefit ratio assessment. Evaluation of clinical performance: design of clinical trials. Project materials drawn from orthopedic devices, soft tissue implants, artificial organs, and dental implants. | en_US |
dc.language | en-US | en_US |
dc.rights.uri | Usage Restrictions: This site (c) Massachusetts Institute of Technology 2003. Content within individual courses is (c) by the individual authors unless otherwise noted. The Massachusetts Institute of Technology is providing this Work (as defined below) under the terms of this Creative Commons public license ("CCPL" or "license"). The Work is protected by copyright and/or other applicable law. Any use of the work other than as authorized under this license is prohibited. By exercising any of the rights to the Work provided here, You (as defined below) accept and agree to be bound by the terms of this license. The Licensor, the Massachusetts Institute of Technology, grants You the rights contained here in consideration of Your acceptance of such terms and conditions. | en_US |
dc.subject | clinical problems | en_US |
dc.subject | implants | en_US |
dc.subject | medical devices | en_US |
dc.subject | cell-matrix control volumes | en_US |
dc.subject | stress analysis | en_US |
dc.subject | Anatomic fit | en_US |
dc.subject | biomaterials | en_US |
dc.subject | surgical implantation procedures | en_US |
dc.subject | Preclinical testing | en_US |
dc.subject | risk/benefit ratio assessment | en_US |
dc.subject | clinical performance | en_US |
dc.subject | clinical trials | en_US |
dc.subject | orthopedic devices | en_US |
dc.subject | soft tissue implants | en_US |
dc.subject | artificial organs | en_US |
dc.subject | dental implants | en_US |
dc.subject | 2.782J | en_US |
dc.subject | 3.961J | en_US |
dc.subject | HST.524J | en_US |
dc.subject | 2.782 | en_US |
dc.subject | 3.961 | en_US |
dc.subject | HST.524 | en_US |
dc.subject | 20.451 | en_US |
dc.subject | 20.451J | en_US |
dc.subject | Medical instruments and apparatus | en_US |
dc.title | 2.782J / 3.961J / 20.451J / HST.524J Design of Medical Devices and Implants, Spring 2003 | en_US |
dc.title.alternative | Design of Medical Devices and Implants | en_US |