Show simple item record

dc.contributor.authorKang, Chʻang-sunen_US
dc.contributor.authorRasmussen, Norman C.en_US
dc.contributor.authorDriscoll, Michael J.en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.otherUnited States. Department of Energyen_US
dc.contributor.otherU.S. Atomic Energy Commissionen_US
dc.date.accessioned2014-09-16T23:32:21Z
dc.date.available2014-09-16T23:32:21Z
dc.date.issueden_US
dc.identifier.urihttp://hdl.handle.net/1721.1/89708
dc.description"November, 1971."en_US
dc.descriptionAlso issued as an Sc. D. thesis by the first author and supervised by the second and third author, MIT Dept. of Nuclear Engineering, 1972en_US
dc.descriptionIncludes bibliographical references (pages 158-162)en_US
dc.description.abstractIt was the purpose of the present investigation to extend and apply Ge(Li) gamma-ray spectroscopy to the study of fast reactor blankets. The focal point for this research was the Blanket Test Facility at the MITR and Blanket No. 2, a realistic mockup of the blanket reflector region of a large liquid metal cooled fast breeder reactor. It was found that Ge(Li) detectors can be simultaneously used as both high energy neutron spectrometers and continuous gamma-ray spectrometers. The broadened internal conversion spectral line at 691.4 KeV has been analyzed for the former purpose, and the Compton recoil continuum has been analyzed and unfolded for the latter. This development makes the Ge(Li) spectrometer an extremely valuable shield analysis tool. The moisture content of the sodium chromate used in the blanket mockup has been confirmed to be less than 0.1 w/o by prompt activation analysis. Prompt capture and inelastic gamma, and decay gamma spectra emitted by the blanket were also analyzed to perform a neutron balance with mixed results. The inability to resolve U-238 prompt capture gammas made it necessary to use the low energy Np-239 decay gammas, with the attendant uncertainties due to large self-shielding corrections. Lack of data on the variation of prompt gamma yield with neutron energy for all blanket constituents also contributed to the uncertainties, which together made it impossible to develop this method to the point where reliable practical application can be recommended.en_US
dc.description.sponsorshipU.S. Atomic Energy Commission contract AT(11-1)-3060en_US
dc.format.extent315 pagesen_US
dc.publisherCambridge, Mass. : Massachusetts Institute of Technology, Dept. of Nuclear Engineering, []en_US
dc.relation.ispartofseriesMITNE ; no. 130en_US
dc.relation.ispartofseriesCOO (Series) ; 3060-2en_US
dc.subject.lccTK9008.M41 N96 no.130en_US
dc.subject.lcshLiquid metal fast breeder reactorsen_US
dc.subject.lcshLiquid metal cooled reactorsen_US
dc.subject.lcshNuclear fuel rodsen_US
dc.titleUse of gamma spectroscopy for neutronic analysis of LMFBR Blanketsen_US
dc.typeTechnical Reporten_US
dc.identifier.oclc856654818en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record