FRANTIC 5 (a version of FRANTIC II) : a computer code for evaluating system aging effect
Author(s)
Dimitrijevic, Vesna B.; Rasmussen, Norman C.; Vesely, W. E.
Download857676093.pdf (8.950Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Nuclear Engineering
EG & G Idaho
Metadata
Show full item recordAbstract
The FRANTIC 5 code is a modification of the FRANTIC II code for time dependent unavailability analysis. FRANTIC 5 is specially adapted for modeling the aging effects on system and component performance. The FRANTIC 5 code uses the linear aging model, i.e., based on the assumption that component failure rates increase linearly in time. The constant failure rate and the aging acceleration rate for a component can be changed during the plant life, which allows the creation of different time scales for components as a function of the replacement or any significant maintenance or repair action on the component. FRANTIC 5 preserves most of the unique features of FRANTIC II, for example the modeling of periodic testing. The output from FRANTIC 5 consists of the system mean unavailabilities, tables of the system unavailabilities at designated time points and the system mean unavailabilities between consecutive tests. The code is applied for evaluation of aging effects of the Auxiliary Feedwater System of Arkansas Nuclear Unit 1. The usefulness of the method will depend upon the availability of the component aging data needed to develop the model parameters.
Description
"November 1986." Includes bibliographical references
Date issued
1986Publisher
Cambridge, Mass. : Dept. of Nuclear Engineering, Massachusetts Institute of Technology, [1986]
Series/Report no.
MITNE ; no. 274